DocumentCode
560729
Title
Notice of Retraction
Design discharge equipment for cold ironing power cable
Author
Luo Ning-zhao ; Zhang Xiao-feng
Author_Institution
Coll. of Electr. & Inf. Eng, Naval Univ. of Eng., Wuhan, China
Volume
2
fYear
2011
fDate
8-9 Sept. 2011
Firstpage
185
Lastpage
188
Abstract
Notice of Retraction
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
When ports supplying shore power to vessel callings used cable to ground exit capacitance, which accumulated charges will have an adverse safety of operating personnel. Article identified 6kV shore power cable parameters arithmetic method, and gives a typical value. By calculating, make sure hazard rating remaining charge to people. Finally, according to the analysis, shore power cable discharge device have principles design, effectively guarantee the safety of the operator.
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
When ports supplying shore power to vessel callings used cable to ground exit capacitance, which accumulated charges will have an adverse safety of operating personnel. Article identified 6kV shore power cable parameters arithmetic method, and gives a typical value. By calculating, make sure hazard rating remaining charge to people. Finally, according to the analysis, shore power cable discharge device have principles design, effectively guarantee the safety of the operator.
Keywords
hazards; personnel; power apparatus; power cables; safety systems; sea ports; adverse safety; cold ironing power cable; discharge equipment; ground exit capacitance; hazard rating; operating personnel; parameters arithmetic method; ports; shore power cable; vessel callings; voltage 6 kV; Capacitance; Discharges; Immune system; Marine vehicles; Power cable insulation; Power cables; Ship craft; cable; discharge device; shore power;