• DocumentCode
    563843
  • Title

    Calculation of water insulation electric strength in electrophysical facilities

  • Author

    Gerasimov, A.I.

  • Author_Institution
    FSUE RFNC - VNIlEF, Sarov, Russia
  • fYear
    2004
  • fDate
    18-23 July 2004
  • Firstpage
    202
  • Lastpage
    204
  • Abstract
    The paper gives a brief review of formulas needed to calculate breakdown strength of electric field purified of mechanical particles of deionized and degassed water depending on: system of electrodes (homogeneous field, coaxial electrodes, spike-surface, blade-surface etc.); duration amplitudes and shapes of applied voltage pulse; electrodes area; thickness of water layer etc.
  • Keywords
    electric breakdown; insulation; water; applied voltage pulse; blade-surface; breakdown strength; coaxial electrodes; degassed water; deionized water; duration amplitudes; electric field; electrodes area; electrophysical facilities; homogeneous field; mechanical particles; spike-surface; water insulation electric strength; water layer thickness; Electric breakdown; Nonuniform electric fields; Weapons;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    High-Power Particle Beams (BEAMS 2004), 2004 International Conference on
  • Conference_Location
    St. Petersburg
  • Print_ISBN
    978-5-87911-088-3
  • Type

    conf

  • Filename
    6220520