• DocumentCode
    565627
  • Title

    Determination of the phase error of 8∶1 Inductive Voltage Divider

  • Author

    Zhang, Jiangtao ; Pan, Xianlin ; Zhang, Deshi ; Hou, Xiaojing

  • Author_Institution
    Nat. Inst. of Metrol., Beijing, China
  • fYear
    2012
  • fDate
    1-6 July 2012
  • Firstpage
    506
  • Lastpage
    507
  • Abstract
    This paper describes the development of Inductive Voltage Divider (IVD) with the ratio of 8:1 by means of the combination of three binary IVDs. The self-calibration method of the ratio error and phase error of the binary IVD was reported. We also report the determination of the phase error of a 8:1 IVD which has relative higher input impedance by comparing with the known phase error self-calibrated 8:1 IVD.
  • Keywords
    calibration; measurement errors; transfer standards; voltage dividers; voltage measurement; inductive voltage divider; input impedance; phase error; ratio error; self-calibration method; Amplifiers; Current measurement; Frequency measurement; Impedance; Inductance; Measurement uncertainty; Voltage measurement; Ratio error; binary inductive voltage divider; measurement uncertainty; phase angle error;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6251025
  • Filename