DocumentCode :
568282
Title :
Monitoring solid flow in a circulating fluidised bed with external heat exchanger by electrical capacitance tomography
Author :
Wang, H.G. ; Qiu, G.Z. ; Zhao, G.R. ; Mou, X.Z. ; Lu, Q.G. ; Yang, W.Q.
Author_Institution :
Inst. of Eng. Thermophys., Beijing, China
fYear :
2012
fDate :
16-17 July 2012
Firstpage :
78
Lastpage :
82
Abstract :
Two circular electrical capacitance tomography (ECT) sensors have been designed and used to monitor the solids flow in a cold circulating fluidised bed (CFB) with an external heat exchanger (EHE). The ECT sensors have eight electrodes and were mounted in the side tube and return tube above the EHE via pneumatically controlled loop seal respectively. Dynamics test with different process conditions are given. Image reconstruction results in the cross-sectional of the two tubes are compared and averaged measured signals are given. The results indicate that the solid flow can be controlled in the EHE based on ECT measurement.
Keywords :
capacitive sensors; electrodes; fluidised beds; heat exchangers; image reconstruction; ECT sensors; averaged measured signals; circular electrical capacitance tomography; cold circulating fluidised bed; dynamics test; electrodes; external heat exchanger; image reconstruction; pneumatically controlled loop seal; solid flow; Electron tubes; Fluidization; Seals; Sensors; Solids; Switches; Valves; CFB; ECT; External heat exchanger; Solid flow;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Imaging Systems and Techniques (IST), 2012 IEEE International Conference on
Conference_Location :
Manchester
Print_ISBN :
978-1-4577-1776-5
Type :
conf
DOI :
10.1109/IST.2012.6295490
Filename :
6295490