Title :
Contact surface condition effect on contact resistance and improving methods
Author :
Bai Xiaoping ; Li Guowei ; Weng Wei ; Zhang Mingjiang ; Lin Wanhuan ; Zhu Libing ; Zhang Yaping
Author_Institution :
Fuda Alloy Mater. Co., Ltd., Wenzhou, China
Abstract :
Electrical contact is an important part in electrical switches, the contact resistance of electrical contacts will not only affect the electrical switches properties, but also play an important role in energy saving of electrical appliance. Therefore, electrical contact manufacturers and electrical appliance manufacturers pay more and more attention to the electrical contact resistance. Especially in the relays field, contact resistance is considered as one of the important indicators of relay quality. This paper discusses the commercial electrical contacts surface foreign materials, surface roughness, surface flatness, as well as the surface film formation process and their effects on contact resistance, and puts forward the main technical indicators which affect contact resistance and the improving methods.
Keywords :
contact resistance; electrical products; energy conservation; relays; surface roughness; switches; commercial electrical contact; contact resistance; electrical appliance; electrical switches properties; energy saving; relay field; relay quality; surface film formation process; surface flatness; surface foreign material; surface roughness; contact resistance; flatness; roughness; surface film; surface foreign materials;
Conference_Titel :
Electrical Contacts (ICEC 2012), 26th International Conference on
Conference_Location :
Beijing
Electronic_ISBN :
978-1-84919-508-9
DOI :
10.1049/cp.2012.0677