• DocumentCode
    572089
  • Title

    Beam profile diagnostics on the NRL SuperIBEX experiment

  • Author

    Peyser, T.A. ; Myers, M.C. ; Pechacek, R.E. ; Murphy, D.P. ; Antoniades, J.A. ; Meger, R.A.

  • Author_Institution
    Plasma Phys. Div., Naval Res. Lab., Washington, DC, USA
  • Volume
    2
  • fYear
    1992
  • fDate
    25-29 May 1992
  • Firstpage
    1263
  • Lastpage
    1269
  • Abstract
    Three independent and complementary diagnostics have been developed to measure the time-dependence of the beam half-current radius produced by the 5 Mev, 100 kA SuperIBEX electron accelerator at the Naval Research Laboratory. A novel five-element segmented concentric Faraday collector has been built which gives the beam half-current radius with nsec time resolution. Two optical streak cameras and an ultra-fast optical framing camera have been used to give time-resolved measurements of the beam radius from Cerenkov emission produced by thin Teflon or quartz foils placed in the beam path.
  • Keywords
    Cameras; Optical filters; Optical imaging; Optical pulses; Optical variables measurement; Stimulated emission; Structural beams;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    High-Power Particle Beams, 1992 9th International Conference on
  • Conference_Location
    Washington, DC, USA
  • Print_ISBN
    000-0-0000-0000-0
  • Type

    conf

  • Filename
    6306651