• DocumentCode
    572279
  • Title

    The Accurate Thermal Performance History Files of Wet Steam Turbine in Nuclear Power Plant

  • Author

    Zhao, Qingsen ; Deng, Debing ; Liu, Yong ; Chen, Wei ; Liu, Gang ; Xiang, Jun ; Su, Sheng ; Sun, Lushi ; Hu, Song

  • Author_Institution
    Mal Power Technol. Center, Suzhou Nucl. Power Res. Inst., Suzhou, China
  • fYear
    2012
  • fDate
    27-29 March 2012
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    There are significant differences between the nuclear power plant turbine and the coal-fired power plant turbine. So the characterization and monitoring models for the coal-fired power plant turbine can not be reused in the nuclear power plant second loop. The unknown wet steam enthalpy and the characteristic of the turbine flow capacity were the two important obstacles for the nuclear power plant wet steam turbine. Based on the accurately measured test data, the accurate thermal performance history files was constructed using the small error heat balance method and the characteristic flow area (CFA). The accurate thermal performance history files were the base for the performance analysis, variable condition calculation, monitoring and diagnosis. The accurate thermal performance history files of Ling Ao unit 3 showed that the unit performance almost was excellent. But the CFA values and the efficiency indicated that some stages of intermediate pressure cylinder (IPT) had leakage in diaphragm, which decreased the unit output. The characteristic parameters of heat regenerative system and moisture separator reheaters system were almost close to the design values, which denoted that the performance of the two systems was acceptable. But the condenser back pressure was larger than the design values, which suggest that the performance was worse than the design condition.
  • Keywords
    nuclear power stations; steam turbines; CFA values; IPT; Ling Ao unit; accurate thermal performance history files; characteristic flow area; coal-fired power plant turbine; condenser back pressure; diaphragm; error heat balance method; heat regenerative system; intermediate pressure cylinder; moisture separator reheater system; monitoring models; nuclear power plant wet steam turbine; thermal performance history; turbine flow capacity; variable condition calculation; wet steam enthalpy; wet steam turbine; Heating; History; Moisture; Ocean temperature; Particle separators; Turbines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Engineering Conference (APPEEC), 2012 Asia-Pacific
  • Conference_Location
    Shanghai
  • ISSN
    2157-4839
  • Print_ISBN
    978-1-4577-0545-8
  • Type

    conf

  • DOI
    10.1109/APPEEC.2012.6307505
  • Filename
    6307505