• DocumentCode
    572553
  • Title

    Microsecond plasma opening switch experiments on GIT-4

  • Author

    Bystritskii, V.M. ; Kim, Alexander A. ; Kokshenev, Vladimir A. ; Koval´chuk, B.M. ; Lisitsyn, I.V. ; Sinebryukhov, A.A. ; Sinebryukhov, Vadim A.

  • Author_Institution
    Institute of Electrophysics RAS, Academy ave.4, Tomsk 634055, RUSSIA
  • Volume
    1
  • fYear
    1996
  • fDate
    10-14 June 1996
  • Firstpage
    127
  • Lastpage
    130
  • Abstract
    The experiments performed allowed us to compare different kinds of plasma sources for high power MPOS applications. High electrode diameters and high switch energy deposition determine types of plasma source which can be used successfully. The analysis of many sets of experiments showes that high voltage/impedanse switch operation can be achieved in limear current density at the POS cathode does not exceed the value of 20 kA/cm. This value limits a maximum cathode diameterer of a MITL. Anode diameter is limited by condition of no gap closure with a dense electrode plasma. Application of external magnetic field decreases plasma density necessary for long POS conduction time operation.
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    High-Power Particle Beams, 1996 11th International Conference on
  • Conference_Location
    Prague, Czech Republic
  • Print_ISBN
    978-80-902250-3-9
  • Type

    conf

  • Filename
    6308286