Title
Robust control using fixed-manifold for wind-power DC-DC converter
Author
Yeh, Fu-Kuang ; Kou, Kuang-Yang ; Huang, Jian-Ji
Author_Institution
Dept. of Comput. Sci. & Inf. Eng., Chung Chou Univ. of Sci. & Technol., Changhua, Taiwan
fYear
2012
fDate
20-23 Aug. 2012
Firstpage
874
Lastpage
879
Abstract
This approach presents a novel scheme based on fixed-manifold robust control for a step-down dc-dc converter, so that the described converter can generate a constant output voltage, which is lower than the input voltage, using closed-loop compensation while guaranteeing stability in a resistance load. The output phase trajectories, which are used to describe the system dynamics and to form a manifold, are to engage in constructing a vector field. To design the fixed-manifold robust control of step-down dc-dc converter, an experimental mathematics model is enough for a practical implementation and those parameters are estimated by curve-fitting method. That is, establishing a very highly precise mathematics model for a buck converter control system isn´t essential. In fact, the model uncertainty can be eliminated by the proposed robust controller. To obtain the competitive control efforts, the methods of predicting the behavior of system dynamics and estimating the lumped uncertainty are adopted during every sampling interval. Finally, by adding an external disturbance in a buck converter system to verify the robustness and excellent stability, various experiments are performed for a wind power generation system to compare the output performance between the fixed-manifold robust controller and the other PI and fuzzy ones.
Keywords
DC-DC power convertors; PI control; closed loop systems; compensation; curve fitting; fuzzy control; parameter estimation; power generation control; robust control; sampling methods; stepping motors; trajectory control; uncertain systems; voltage control; wind power; PI control; buck converter system; closed-loop compensation; constant output voltage; curve-fitting method; external disturbance; fixed-manifold robust control; fuzzy control; lumped uncertainty; mathematics model; output phase trajectory; parameter estimation; resistance load; sampling interval; stability; step-down dc-dc converter; system dynamics behavior prediction; vector field; wind power generation system; wind-power DC-DC converter; Control systems; Equations; Mathematical model; Robustness; Uncertainty; Voltage control; Wind power generation; curve-fitting method; fixed-manifold robust control; step-down dc-dc converter; wind power generation system;
fLanguage
English
Publisher
ieee
Conference_Titel
SICE Annual Conference (SICE), 2012 Proceedings of
Conference_Location
Akita
ISSN
pending
Print_ISBN
978-1-4673-2259-1
Type
conf
Filename
6318564
Link To Document