DocumentCode :
575432
Title :
Static strain measurement by fiber Bragg Gratings using multiplexed common-path interferometers
Author :
Shinoda, Y. ; Yamada, M. ; Arai, T. ; Higo, T.
Author_Institution :
Coll. of Sci. & Technol., Nihon Univ., Tokyo, Japan
fYear :
2012
fDate :
20-23 Aug. 2012
Firstpage :
1021
Lastpage :
1024
Abstract :
We demonstrated the effects of multiplexing interference on the reflected spectra of multi-point fiber Bragg Gratings (FBGs) with common-path interferometer multiplexing. This paper is described that our system is able to measure the reflected spectra and the reflected wavelengths ever 2 s without the effects of multiplexing interference by introducing offset fiber.
Keywords :
Bragg gratings; condition monitoring; interferometers; optical fibres; spectra; strain measurement; structural engineering; fiber Bragg gratings; multiplexed common-path interferometer; multiplexing interference effect; multipoint FBG; offset fiber; reflected spectra; reflected wavelength; static strain measurement; structural health monitoring system; Fiber gratings; Interference; Interferometers; Multiplexing; Optical fibers; Wavelength measurement; fiber Bragg grating; strain measurement; structural health monitoring; wavelength measurement;