Abstract :
In this paper, influences of filter installation errors on image quality are studied for airborne multispectral imager. The results show that focus length changes has little influence on image quality, and focus movements caused by filter installation errors have bigger influence on image quality and resolution. In order to get better images, filters should be installed carefully, and keep them parallel with the image plane. Influences of mechanical vibration on filter distortion should be avoided as well.
Keywords :
CMOS image sensors; filtering theory; image resolution; space vehicles; spectral analysis; airborne multispectral imager; filter installation error; focus movement; image quality; image resolution; Adaptive optics; Image quality; Multispectral imaging; Optical filters; Optical imaging; Optical sensors;