DocumentCode
577333
Title
Effects of parasitic circuit elements in RF energy harvesting circuit
Author
Muramatsu, Masaki ; Nishiyama, Hiroki ; Koizumi, Hirotaka
Author_Institution
Dept. of Electr. Eng., Tokyo Univ. of Sci., Tokyo, Japan
fYear
2012
fDate
24-27 Sept. 2012
Firstpage
18
Lastpage
22
Abstract
This paper presents effects of the parasitic circuit element parameter in RF (Radio Frequency) energy harvesting circuit. The RF energy harvesting circuit is composed of a loop antenna, a 6-stage Dickson charge pump and an output capacitor as an energy storage element. The parasitic circuit element parameter effects are discussed based on PSIM simulation, experiments with an equivalent RF power source and experiments on site. These results show the leakage current of the output capacitor and forward voltage drop of the diode affect the output voltage, and the junction capacitance of the diode affects the resonant frequency. In addition, the effects of parallel connection of two RF energy harvesting circuits are introduced.
Keywords
capacitors; charge pump circuits; energy harvesting; loop antennas; power semiconductor diodes; 6-stage Dickson charge pump; PSIM simulation; RF energy harvesting circuit; RF power source; diode; energy storage element; forward voltage drop; junction capacitance; leakage current; loop antenna; output capacitor; parasitic circuit element parameter effects; radiofrequency energy harvesting circuit; resonant frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Sustainable Energy Technologies (ICSET), 2012 IEEE Third International Conference on
Conference_Location
Kathmandu
ISSN
2165-4387
Print_ISBN
978-1-4577-1870-0
Electronic_ISBN
2165-4387
Type
conf
DOI
10.1109/ICSET.2012.6357369