DocumentCode :
58104
Title :
Quantifying the Deep Tendon Reflex Using Varying Tendon Indentation Depths: Applications to Spasticity
Author :
Chardon, Matthieu K. ; Rymer, William Z. ; Suresh, Nina L.
Author_Institution :
Dept. of Biomed. Eng., Northwestern Univ., Evanston, IL, USA
Volume :
22
Issue :
2
fYear :
2014
fDate :
Mar-14
Firstpage :
280
Lastpage :
289
Abstract :
The deep tendon reflex (DTR) is often utilized to characterize the neuromuscular health of individuals because it is cheap, quick to implement, and requires limited equipment. However, DTR assessment is unreliable and assessor-dependent improve the reliability of the DTR assessment, we devised a novel standardization procedure. Our approach is based on the hypothesis that the neuromuscular state of a muscle changes systematically with respect to the indentation depth of its tendon. We tested the hypothesis by progressively indenting the biceps tendons on each side of nine hemiplegic stroke survivors to different depths, and then superimposing a series of brief controlled taps at each indentation depth to elicit a reflex response. Our results show that there exists a unique indentation depth at which reflex responses are consistently recorded (termed the Reflex Threshold) with increasing amplitude along increasing indentation depth. We further show that the reflex threshold depth is systematically smaller on the affected side of stroke survivors and that it is negatively correlated with the Modified Ashworth Score (VAF 70%). Our procedure also enables measurement of passive mechanical properties at the indentation location. In conclusion, our study shows that controlling for the indentation depth of the tendon of a muscle alters its reflex response predictably. Our novel device and method could be used to estimate neuromuscular changes in muscle (e.g., spasticity). Although some refinement is needed, this method opens the door to more reliable quantification of the DTR.
Keywords :
biomechanics; biomedical equipment; biomedical measurement; indentation; mechanoception; medical disorders; muscle; neurophysiology; standardisation; DTR assessment reliability improvement; DTR quantification; assessor dependence; bicep tendons; consistent reflex response recording; deep tendon reflex quantification; hemiplegic stroke survivors; indentation depth tap controlled; indentation location passive mechanical properties; medical device; medical method; modified Ashworth score; muscle; neuromuscular change estimation; neuromuscular health; passive mechanical properties measurement; reflex threshold depth; spasticity; standardization procedure; stroke survivor affected side; tap amplitude; tendon indentation depth control; tendon indentation depths; tendon reflex response; Actuators; Electromyography; Force; Force measurement; Muscles; Protocols; Tendons; Deep tendon reflex; reflex threshold; skeletal muscle mechanical properties; spasticity; stroke;
fLanguage :
English
Journal_Title :
Neural Systems and Rehabilitation Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
1534-4320
Type :
jour
DOI :
10.1109/TNSRE.2014.2299753