Abstract :
One of the most used power converters is the three-phase voltage source power inverter. This is one of the reasons why it is so important to assure a continuous and safety operation of this power converter. This paper considers the application of PCA and average value computation to detect and identify faulty power switches in voltage source inverters. The PCA is applied to the inverter output currents in order to get a specific pattern that allows the identification of the fault. This results in a fast and reliable fault detection methodology. The applicability of the proposed technique is confirmed through simulation and experimental results.
Keywords :
fault diagnosis; invertors; power grids; principal component analysis; reliability; safety; PCA; average value computation; continuous operation; current mean value; fault detection; fault diagnosis; grid-connected power inverters; reliable fault detection methodology; safety operation; three phase voltage source power inverter; MATLAB; Reliability; Switches; PCA; Voltage source inverter; fault diagnosis; power switches;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
Conference_Location :
Montreal, QC
ISSN :
1553-572X
Print_ISBN :
978-1-4673-2419-9
Electronic_ISBN :
1553-572X
Type :
conf
DOI :
10.1109/IECON.2012.6388972
Filename :
6388972
Link To Document :
بازگشت