• DocumentCode
    582220
  • Title

    A near-infrared quality assessment method for palm-dorsa vein image

  • Author

    Qi, Li ; Jianjiang, Cui ; Dingyu, Xue ; Xu, Jia

  • fYear
    2012
  • fDate
    25-27 July 2012
  • Firstpage
    3917
  • Lastpage
    3921
  • Abstract
    In this paper, we present a new quality assessment method for palm-dorsa vein image based on multi-feature fusion according to the characteristics of palm-dorsa vein image. We develop a quality assessment function by computing the four parameters of gray variance, information entropy, cross point and area of effect respectively and then weighted fusing. We then feed the function value back to the regulating device with near-infrared light source. The experiment results show that this new method is efficient for getting ideal palm-dorsa vein image by regulating light intensity.
  • Keywords
    image fusion; information theory; medical image processing; gray variance; information entropy; multifeature fusion; near-infrared light source; near-infrared quality assessment method; palm-dorsa vein image; quality assessment function; Abstracts; Educational institutions; Electronic mail; Image recognition; Quality assessment; Reactive power; Veins; Image quality assessment; Multi-feature fusion; Near-infrared; Palm-dorsa vein recognition;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control Conference (CCC), 2012 31st Chinese
  • Conference_Location
    Hefei
  • ISSN
    1934-1768
  • Print_ISBN
    978-1-4673-2581-3
  • Type

    conf

  • Filename
    6390610