Title :
Operating characteristics of a high power X-band gyroklystron
Author :
Lawson, W. ; Latham, P.E. ; Calame, J. ; Welsh, D. ; Hogan, B. ; Miller, S.M. ; Main, W. ; Striffler, C.D. ; Reiser, M. ; Granatstein, V.L.
Author_Institution :
Lab. for Plasma Res., Univ. of Maryland, College Park, MD, USA
Abstract :
At the University of Maryland we have designed1) and are operating a high power two-cavity TE01 gyroklystron in the 9.7-10.0 GHz range. The target beam power is derived from a 500 kV beam with a current ranging from 120-240 A in 1 μs pulses. The target microwave parameters for this tube include a power level of 15-30 MW with a gain of 25-30 dB. In this paper we describe the initial characterization of the electron gun performance and detail preliminary microwave amplifier experiments. We also discuss modifications recently made to the two cavity circuit to improve stability.
Keywords :
circuit stability; electron guns; gyrotrons; klystrons; microwave amplifiers; microwave tubes; University of Maryland; cavity circuit stability; current 120 A to 240 A; electron gun performance; frequency 9.7 GHz to 10.0 GHz; gain 25 dB to 30 dB; high power two-cavity TE01 X-band gyroklystron; microwave amplifier experiment; power 15 MW to 30 MW; target microwave parameter; time 1 mus; voltage 500 kV; Cavity resonators; Klystrons; Microwave amplifiers; Microwave circuits; Microwave oscillators;
Conference_Titel :
High-Power Particle Beams, 1990 8th International Conference on
Conference_Location :
Novosibirsk
Print_ISBN :
9.7898102055e+012