• DocumentCode
    586388
  • Title

    Video segmentation of the common carotid artery intima media complex

  • Author

    Loizou, Christos P. ; Kasparis, T. ; Papakyriakou, P. ; Christodoulou, Loucas ; Pantziaris, Marios ; Pattichis, C.S.

  • Author_Institution
    Dept. of Electr. Eng., Cyprus Univ. of Technol., Limassol, Cyprus
  • fYear
    2012
  • fDate
    11-13 Nov. 2012
  • Firstpage
    500
  • Lastpage
    505
  • Abstract
    The correct identification of the intima-media thickness (IMT) of the common carotid artery (CCA) walls has a high clinical relevance as it represents one of the most reliable predictor for future cardiovascular events. In this work we propose and evaluate an integrated system for the segmentation of the intima-media complex (IMC) and the lumen diameter in longitudinal ultrasound video of the CCA based on normalization, speckle reduction filtering (with a first order statistics filter) and snakes segmentation. The algorithm is initialized in the first video frame of the cardiac cycle by an automated initialization procedure and the borders of the far wall and near wall of the CCA are estimated. The IMC and the carotid diameter are then segmented automatically in the consecutive video frames for one cardiac cycle. The proposed algorithm was evaluated on 10 longitudinal ultrasound B-mode videos of the CCA and is compared with the manual tracings of a neurovascular expert, for every 20 frames in a time span of 3-5 seconds, covering in general 1-2 cardiac cycles. The algorithm estimated an IMTmean± standard deviation of (0.72±0.22) mm while the manual results were (0.70±0.19). The mean maximum and minimum diameter was (7.08±1.37) mm and (6.53±1.13) mm respectively. The results were validated based on statistical measures and univariate statistical analysis. It was shown that there was no significant difference between the snakes segmentation measurements and the manual measurements. The proposed integrated system could successfully segment the IMC in ultrasound CCA video sequences thus complementing manual measurements.
  • Keywords
    biomedical ultrasonics; blood vessels; cardiovascular system; filtering theory; image segmentation; image sequences; medical image processing; statistical analysis; ultrasonic imaging; video signal processing; CCA walls; IMC; automated initialization procedure; cardiac cycle; cardiovascular events; carotid diameter; common carotid artery intima media complex; consecutive video frames; longitudinal ultrasound B-mode videos; lumen diameter; manual measurements; snakes segmentation measurements; speckle reduction filtering; statistical measures; ultrasound CCA video sequences; univariate statistical analysis; video segmentation; Carotid arteries; Filtering; Image segmentation; Manuals; Ultrasonic imaging; Ultrasonic variables measurement; Iintima-media thickness; carotid artery; ultrasound video;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Bioinformatics & Bioengineering (BIBE), 2012 IEEE 12th International Conference on
  • Conference_Location
    Larnaca
  • Print_ISBN
    978-1-4673-4357-2
  • Type

    conf

  • DOI
    10.1109/BIBE.2012.6399728
  • Filename
    6399728