• DocumentCode
    587964
  • Title

    IBEX - Annular beam propagation experiment

  • Author

    Mazarakis, M. G. ; Miller, R. B. ; Shope, S. L. ; Poukey, J. W. ; Ramirez, J. J. ; Ekdahl, C. A. ; Adler, R. J.

  • Author_Institution
    Sandia National Laboratories, Albuquerque, New Mexico 87185, USA
  • fYear
    1983
  • fDate
    12-14 Sept. 1983
  • Firstpage
    346
  • Lastpage
    349
  • Abstract
    IBEX is a 4-MV, 100-kA, 20-ns cylindrical isolated Blumlein accelerator. In the experiments reported here, the accelerator is fitted with a specially designed foilless diode which is completely immersed in a uniform magnetic field. several diode geometries have been studied as a function of magnetic field strength. The beam propagates a distance of 50 an (∼ 10 cyclotron wavelengths) in vacuum before either striking a beam stop or being extracted through a thin foil. The extracted beam was successfully transported 60 an downstream into a drift pipe filled either with 80 or 640 torr air. The main objectives of this experiment were to establish the proper parameters for the most quiescent 4 MV, 20–40 kA annular beam, and to compare the results with available theory and numerical code simulations.
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    High-Power Particle Beams, 1983. HPPB. 5th International Conference on
  • Conference_Location
    San Francisco, CA, USA
  • Type

    conf

  • Filename
    6403729