Title :
Validation of the PR-RR hysteresis phenomenon
Author :
Cabasson, A. ; Meste, O. ; Bailon, Raquel ; Laguna, P.
Author_Institution :
Lab. I3S, UNS, Sophia Antipolis, France
Abstract :
Previous studies on ECG recorded under exercise conditions on sedentary and athlete subjects lead to following results: 1) the subjects can be characterized according to their training level studying the PR slope in the early recovery phase, and 2) it exists a non-linear relationship between PR and RR intervals which exhibits a clockwise hysteresis shape when data from exercise and its recovery are compared. The main drawback of these studies is that they were performed on a small size data set. As the understanding of the PR-RR hysteresis phenomenon may lead to improvement of pacemaker´s design, the aim of this study is to check the PR-RR hysteresis on a larger data set.
Keywords :
biomechanics; electrocardiography; medical signal processing; ECG recording; PR-RR hysteresis phenomenon validation; athlete subjects; data set; exercise conditions; pacemaker design; recovery phase; sedentary subjects; training level; Aging; Electrocardiography; Estimation; Heart rate; Hysteresis; Standards; Training;
Conference_Titel :
Computing in Cardiology (CinC), 2012
Conference_Location :
Krakow
Print_ISBN :
978-1-4673-2076-4