• DocumentCode
    591305
  • Title

    Automated tracking of deformable objects based on non-rigid registration of cardiac images

  • Author

    Tarroni, G. ; Patel, Ankeeta R. ; Yodwut, C. ; Lang, R.M. ; Lamberti, Claudio ; Mor-Avi, Victor ; Corsi, C.

  • Author_Institution
    Univ. of Bologna, Bologna, Italy
  • fYear
    2012
  • fDate
    9-12 Sept. 2012
  • Firstpage
    693
  • Lastpage
    696
  • Abstract
    We developed an automated technique for non-rigid image registration as a basis for tracking the heart in contrast-enhanced cardiac magnetic resonance (CMR) image sequences. The goal of the present work was to validate this technique against conventional manual analysis. Our approach is based on a multi-scale extension of the normalized 2D cross-correlation algorithm in combination with level-set methods. This technique was tested on short-axis CMR (Philips 1.5T) image sequences obtained in 11 patients at the mid level of the left ventricle during first pass of a gadolinium bolus. Myocardial identification required around 5s for a 60-frame sequence. To validate the technique, myocardial boundaries were manually traced on all frames by an experienced interpreter. Comparison between automatically registered and manually traced boundaries was performed by computing Hausdorff distance (2.1±1.4px), mean absolute distance (0.9±0.7px), root mean square distance (1.0±0.8px) and Dice coefficient (0.8±0.1). These results indicate that the proposed technique allows fast and accurate non-rigid image registration, and may thus be successfully used for deformable object tracking in cardiac image sequences.
  • Keywords
    biomechanics; biomedical MRI; cardiology; deformation; image registration; image sequences; medical image processing; automated tracking; cardiac image sequences; cardiac images; contrast-enhanced cardiac magnetic resonance; deformable object tracking; deformable objects; gadolinium bolus; left ventricle; level-set methods; myocardial boundaries; myocardial identification; nonrigid registration; normalized 2D cross-correlation algorithm; short-axis CMR image sequences; Image registration; Image sequences; Imaging; Manuals; Measurement; Myocardium; Root mean square;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computing in Cardiology (CinC), 2012
  • Conference_Location
    Krakow
  • ISSN
    2325-8861
  • Print_ISBN
    978-1-4673-2076-4
  • Type

    conf

  • Filename
    6420488