Abstract :
Level measurements of liquid material are one of the important parameters in a process industry. Low cost admittance type liquid level measuring system using single electrode with conducting vessel and double electrode with insulating vessel already exist. In the present work, attempts have been made to study the cross sensitivity of temperature in the admittance type liquid level measurement. The cross sensitivity in the admittance measurement due to temperature is considered for admittance calculations. Error curves due to cross sensitivity for both single electrode and double electrode are simulated using MATLAB. The cross sensitivity due to temperature has been found significant and can be used for simultaneous measurement of temperature and liquid level.
Keywords :
electrodes; level measurement; measurement errors; temperature measurement; MATLAB simulation; admittance type level measurement; admittance type liquid level measurement system; conducting vessel; cross sensitivity; double electrode; error curve; insulating vessel; liquid material; single electrode; temperature measurement; Admittance; Electrodes; Level measurement; Liquids; Sensitivity; Temperature measurement; Temperature sensors; Admittance; Conductivity; Cross sensitivity; Liquid level measurement; Permittivity;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Sensing Technology (ICST), 2012 Sixth International Conference on
Conference_Location :
Kolkata
ISSN :
2156-8065
Print_ISBN :
978-1-4673-2246-1
Type :
conf
DOI :
10.1109/ICSensT.2012.6461677
Filename :
6461677
Link To Document :
بازگشت