• DocumentCode
    600858
  • Title

    Gas evolution of nickel, stainless steel 316 and titanium anodes in vacuum sealed tubes

  • Author

    Parson, Jonathan ; Dickens, James ; Walter, John ; Neuber, Andreas ; Kristiansen, Magne

  • Author_Institution
    Texas Tech University, Department of Electrical and Computer Engineering, Lubbock, TX 79424, USA
  • fYear
    2012
  • fDate
    3-7 June 2012
  • Firstpage
    239
  • Lastpage
    240
  • Abstract
    This paper presents a study on gas evolution of three different anode materials in vacuum sealed tubes under UHV conditions. The experimental apparatus consists of a high-power microwave (HPM) virtual-cathode oscillator (vircator) driven by a 200 ns, 80 J, 225 kV low-impedance Marx Generator. Plasma expansion due to explosive electron field emission has shown to lower gap impedance, spoil consistent low vacuum levels, and cut-off microwave radiation. The anode materials compared are nickel 201L (Ni201L), stainless steel 316L (SS316L) and grade-1 titanium (TiG1); with the cathode material being aluminum. The anodes were cleaned by the following method: rough polishing followed by electro-polishing, a ten minute microwave argon / 10% oxygen plasma cleaning process (ArO2) and finally, a 72 hour in situ bake-out at 300°C. Outgassing characteristics of each anode material are presented and compared.
  • Keywords
    High-power microwaves (HPMs); vacuum diode; virtual cathode oscillator (vircator);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Modulator and High Voltage Conference (IPMHVC), 2012 IEEE International
  • Conference_Location
    San Diego, CA, USA
  • Print_ISBN
    978-1-4673-1222-6
  • Type

    conf

  • DOI
    10.1109/IPMHVC.2012.6518724
  • Filename
    6518724