• DocumentCode
    600927
  • Title

    Lifetime testing of Airix accelerating units

  • Author

    Georges, Alquie ; Dzitko, H. ; Mouillet, M. ; Reynaud, D. ; Nicolas, R.

  • Author_Institution
    CEA DAM Île-de-France, F-91297, Arpajon, (site du Polygone d´Expérimentation de Moronvilliers), France
  • fYear
    2012
  • fDate
    3-7 June 2012
  • Firstpage
    805
  • Lastpage
    807
  • Abstract
    Airix is a linear accelerator producing a 60ns, 2kA, 19MeV electron beam. It has been operated in a single shot mode by the “Commissariat à l´Energie Atomique et aux Energies Alternatives” (CEA) for flash X-ray radiography purposes for nearly 12 years [1, 3]. Usually each accelerating unit (a cell and its driver) delivers a 100ns pulse of 250kV amplitude to the beam. The test bench is used to determine the behaviour over time of the cells, the driver (high voltage generator) and the links between them (high voltage cables). We try different configurations and deal with ensuing problems. In this paper, we describe the test-bed in use, the problems we have met and how we dealt with them, and we establish the reliability performances we now expect from the accelerating units for the next decades.
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Modulator and High Voltage Conference (IPMHVC), 2012 IEEE International
  • Conference_Location
    San Diego, CA, USA
  • Print_ISBN
    978-1-4673-1222-6
  • Type

    conf

  • DOI
    10.1109/IPMHVC.2012.6518868
  • Filename
    6518868