• DocumentCode
    601909
  • Title

    Load current-sensor-less feed-forward method for fast load transient response using digital control

  • Author

    Choi, KyuSik ; Kim, Hye-Jin ; Cho, Bo H.

  • Author_Institution
    School of Electrical Engineering and Computer Science, Seoul National University, #043, San 56-1, Shillim-dong, Gwanak-gu, 151-742, Korea
  • fYear
    2013
  • fDate
    17-21 March 2013
  • Firstpage
    2769
  • Lastpage
    2772
  • Abstract
    In this paper, a simple load current feed-forward control method to enhance the load transient response is proposed. Different from the conventional load current feed-forward control method, the proposed method calculates load current variation from the output voltage rather than directly measuring load current which requires a current sensor, such as a Hall-effect sensor. The proposed method requires only an op-amp, signal level resistors and capacitors. The performance of the proposed method is verified experimentally with a 12 V input to 24 V output boost converter. The proposed method reduces output voltage overshoot during a load transient as effective as conventional load current sensed feed-forward control method.
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition (APEC), 2013 Twenty-Eighth Annual IEEE
  • Conference_Location
    Long Beach, CA, USA
  • ISSN
    1048-2334
  • Print_ISBN
    978-1-4673-4354-1
  • Electronic_ISBN
    1048-2334
  • Type

    conf

  • DOI
    10.1109/APEC.2013.6520688
  • Filename
    6520688