DocumentCode :
601963
Title :
Assessment of waveform control method for mitigation of low-frequency current ripple
Author :
Zhu, G.R. ; Wang, H.R. ; Xiao, C.Y. ; Siew-Chong Tan ; Kang, Yue
Author_Institution :
Dept. of Electr. Eng., Wuhan Univ. of Technol., Wuhan, China
fYear :
2013
fDate :
17-21 March 2013
Firstpage :
3101
Lastpage :
3106
Abstract :
Waveform control method can mitigate such a low-frequency ripple current being drawn from the DC distribution while the DC distribution system delivers AC power to the load through a differential inverter. Assessment on the waveform control method and comparative study between with and without waveform control method are proposed in this paper1. Experimental results are provided to explain the operation and showcase the performance between with and without the waveform control method. Results validate that the waveform control solution can achieve significant mitigation of the current ripple as well as high quality output voltage without extra hardware. Lower current stress of the switch and higher efficiency can be obtained with waveform control method than without waveform control method.
Keywords :
electric current control; invertors; switches; AC power; DC distribution system; differential inverter; high quality output voltage; low-frequency current ripple mitigation; switch current stress; waveform control method assessment;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Power Electronics Conference and Exposition (APEC), 2013 Twenty-Eighth Annual IEEE
Conference_Location :
Long Beach, CA
ISSN :
1048-2334
Print_ISBN :
978-1-4673-4354-1
Electronic_ISBN :
1048-2334
Type :
conf
DOI :
10.1109/APEC.2013.6520743