Abstract :
In order to compare radiation measurements in powerline communication systems, the detected values in the applied measurement distance need to be converted to a normative distance using an extrapolation factor. In this paper we determine the extrapolation factor within the frequency range 150 kHz to 500 kHz using analytical, numerical and experimental approaches.
Keywords :
carrier transmission on power lines; extrapolation; PLC radiation measurements; applied measurement distance; extrapolation factor; frequency 150 kHz to 500 kHz; powerline communication systems; Antenna measurements; Electric fields; Electric variables measurement; Extrapolation; Frequency measurement; Magnetic field measurement; Magnetic fields; Electromagnetic compatibility; Extrapolation factor; Powerline communications; Radiation measurement;