• DocumentCode
    605432
  • Title

    P-Q theory for shunt active filters using ramp comparator

  • Author

    Joseph, D. ; Kalaiarasi, N.

  • fYear
    2013
  • fDate
    6-8 Feb. 2013
  • Firstpage
    601
  • Lastpage
    606
  • Abstract
    Here a P-Q algorithm for shunt active power filters under stiff and non stiff source is described. The conventional current reference algorithms suffer from the disadvantage that it is not possible for harmonic compensation when the supply is unbalanced. A ramp comparison method is incorporated in this method to avoid the disadvantages caused by the conventional hysteresis control method. A comparison of different current reference generation algorithms is also done. The simulation works has been done in MATLAB/SIMULINK software.
  • Keywords
    active filters; comparators (circuits); hysteresis; power harmonic filters; MATLAB-SIMULINK software; P-Q theory; current reference generation algorithms; harmonic compensation; hysteresis control method; ramp comparator; shunt active power filters; Active filters; Control systems; Harmonic analysis; Hysteresis; Inverters; Power harmonic filters; Switching frequency; P-Q theory; harmonics; hysteresis; ramp comparator; shunt active power filter;