DocumentCode
607525
Title
Repetition rate method of the air flow velocity measurement
Author
Hribik, J. ; Bobek, P. ; Fuchs, Philippe
Author_Institution
Inst. of Electron. & Photonics, Eng. & Inf. Technol. SUT, Bratislava, Slovakia
fYear
2013
fDate
16-17 April 2013
Firstpage
162
Lastpage
165
Abstract
Repetition rate method of the air flow velocity measurement (the air flows inside a rectangular tube) is investigated. Two oscillators, each of which consists of a driver stage, ultrasound transmitter and receiver and an amplifier, use a feedback downstream and upstream the air flow, respectively. A difference frequency is subsequently derived. The advantage of this method is the cancelation of the influences of such factors as temperature, humidity, pollution, etc. of the flowing air on the difference frequency. The attempt to describe the influence of nonsymmetry concerning the propagation path lengths and sensitivity analysis is made and the derived equations are given.
Keywords
flow measurement; oscillators; pipes; receivers; sensitivity analysis; temperature; transmitters; ultrasonic devices; velocity measurement; air flow velocity measurement; amplifier; difference frequency; driver stage; feedback downstream; feedback upstream; flowing air; humidity; oscillators; pollution; propagation path lengths; rectangular tube; repetition rate method; sensitivity analysis; temperature; ultrasound receiver; ultrasound transmitter; Fluid flow measurement; Oscillators; Pollution measurement; Receivers; Transmitters; Ultrasonic imaging; Velocity measurement; air flow velocity measurement; oscillator; repetition rate method; sensitivity analysis; ultrasound receiver; ultrasound transmitter;
fLanguage
English
Publisher
ieee
Conference_Titel
Radioelektronika (RADIOELEKTRONIKA), 2013 23rd International Conference
Conference_Location
Pardubice
Print_ISBN
978-1-4673-5516-2
Type
conf
DOI
10.1109/RadioElek.2013.6530908
Filename
6530908
Link To Document