Title :
Development of the Space active Hydrogen Maser for the ACES Mission
Author :
Goujon, D. ; Rochat, Pascal ; Mosset, Pierre ; Boving, D. ; Perri, A. ; Rochat, J. ; Ramanan, Narayanan ; Simonet, D. ; Vernez, X. ; Froidevaux, Sylvere ; Perruchoud, G.
Author_Institution :
SpectraTime SA, Neuchatel, Switzerland
Abstract :
The Atomic Clock Ensemble in Space (ACES) is composed of two atomic clocks: one cold Caesium clock (PHARAO) and one active Space Hydrogen Maser (SHM). PHARAO is necessary to ensure outstanding long-term frequency stability (τ ≥ 3000 s) and accuracy, while SHM is mandatory for its ultimate frequency stability in the mid-term range (3 s ≤ τ ≤ 3000 s). The combination of the two clocks via a double servo loop (short-term and long-term), will ensure an ultimate frequency stability. This configuration takes advantage of the best frequency stability for each integration time (PHARAO frequency locked to SHM for the short and mid-term, and SHM frequency steered to PHARAO for the long-term).
Keywords :
aerospace instrumentation; atomic clocks; frequency stability; ACES mission; PHARAO; active space hydrogen maser; atomic clock ensemble in space; cold caesium clock; long-term frequency stability; space active hydrogen maser;
Conference_Titel :
EFTF-2010 24th European Frequency and Time Forum
Conference_Location :
Noordwijk
Print_ISBN :
978-1-4673-5970-2
DOI :
10.1109/EFTF.2010.6533730