• DocumentCode
    61156
  • Title

    A methodology for evaluating detection performance of ultrasonic array imaging algorithms for coarse-grained materials

  • Author

    Van Pamel, Anton ; Brett, Colin R. ; Lowe, Michael J. S.

  • Author_Institution
    Dept. of Mech. Eng., Imperial Coll. London, London, UK
  • Volume
    61
  • Issue
    12
  • fYear
    2014
  • fDate
    Dec. 2014
  • Firstpage
    2042
  • Lastpage
    2053
  • Abstract
    Improving the ultrasound inspection capability for coarse-grained metals remains of longstanding interest and is expected to become increasingly important for next-generation electricity power plants. Conventional ultrasonic A-, B-, and C-scans have been found to suffer from strong background noise caused by grain scattering, which can severely limit the detection of defects. However, in recent years, array probes and full matrix capture (FMC) imaging algorithms have unlocked exciting possibilities for improvements. To improve and compare these algorithms, we must rely on robust methodologies to quantify their performance. This article proposes such a methodology to evaluate the detection performance of imaging algorithms. For illustration, the methodology is applied to some example data using three FMC imaging algorithms; total focusing method (TFM), phase-coherent imaging (PCI), and decomposition of the time-reversal operator with multiple scattering filter (DORT MSF). However, it is important to note that this is solely to illustrate the methodology; this article does not attempt the broader investigation of different cases that would be needed to compare the performance of these algorithms in general. The methodology considers the statistics of detection, presenting the detection performance as probability of detection (POD) and probability of false alarm (PFA). A test sample of coarse-grained nickel super alloy, manufactured to represent materials used for future power plant components and containing some simple artificial defects, is used to illustrate the method on the candidate algorithms. The data are captured in pulse-echo mode using 64-element array probes at center frequencies of 1 and 5 MHz. In this particular case, it turns out that all three algorithms are shown to perform very similarly when comparing their flaw detection capabilities.
  • Keywords
    flaw detection; granular materials; nickel alloys; superalloys; ultrasonic materials testing; 64-element array probes; FMC imaging algorithms; coarse-grained materials; detection performance; detection probability; detection statistics; false alarm probability; flaw detection; frequency 1 MHz; frequency 5 MHz; full matrix capture imaging algorithms; multiple scattering filter; nickel superalloy; phase-coherent imaging; pulse-echo mode; time-reversal operator decomposition; total focusing method; ultrasonic array imaging algorithms; ultrasound inspection capability; Acoustics; Arrays; Imaging; Inspection; Materials; Noise; Scattering;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2014.006429
  • Filename
    6968698