DocumentCode :
612017
Title :
Experimental investigations of accuracy improvement and limitations of a free space measurement system including thin lenses
Author :
Ajami, Alain ; Akkara-Aketalin, T. ; Shakhtour, Hammam ; Heberling, Dirk
Author_Institution :
Inst. of High-Freq. Technol., RWTH Aachen Univ., Aachen, Germany
fYear :
2013
fDate :
8-12 April 2013
Firstpage :
4064
Lastpage :
4067
Abstract :
In this paper a free space measurement system, including two horn antennas and two lenses, is considered. It has been shown that an experimental investigation of the fabricated lenses is of paramount importance, since fabrication inaccuracies could lead to system performance deterioration. A method to determine the focal length of the fabricated lenses, the operational frequency and the separations between horns and lenses and the lenses themselves, without a priori information about the phase centers of the horn antennas, has been given. It has been shown that for the alignment of such a system the phase centers of the horns are not needed at all. The proposed experimental alignment method in this paper improved the accuracy of the material measurements. Finally limitations on the thickness of the MUT for certain accuracy were discussed.
Keywords :
horn antennas; lenses; spatial variables measurement; focal length; free space measurement system; horn antennas; performance deterioration; thin lenses; Accuracy; Antenna measurements; Extraterrestrial measurements; Frequency measurement; Horn antennas; Lenses; Materials;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Antennas and Propagation (EuCAP), 2013 7th European Conference on
Conference_Location :
Gothenburg
Print_ISBN :
978-1-4673-2187-7
Electronic_ISBN :
978-88-907018-1-8
Type :
conf
Filename :
6547075