DocumentCode :
617150
Title :
Determination of the synchronization criteria of line start IPM motors
Author :
Rabbi, S.F. ; Rahman, Md Arifur
Author_Institution :
Fac. of Eng. & Appl. Sci., Memorial Univ. of Newfoundland, St. John´s, NL, Canada
fYear :
2013
fDate :
12-15 May 2013
Firstpage :
1218
Lastpage :
1224
Abstract :
This paper provides analytical, simulation and experimental results to investigate the synchronization capability of line start IPM motors for different loading conditions. Approximate solution techniques based on average torque analysis for determining the critical slip and maximum inertia of a line start IPM motor for various types of load are also presented. A d-q axis model including the cage resistance and reactance is developed to analyze the run up responses of a 1 hp, 3-phase, 4-pole line start interior permanent magnet synchronous motor. Experimental investigations have been also carried out for the same 1 hp IPM motor and test results are presented to support simulation results.
Keywords :
approximation theory; permanent magnet motors; synchronisation; synchronous motors; 3-phase 4-pole line start interior permanent magnet synchronous motor; approximate solution technique; cage reactance; cage resistance; critical slip; d-q axis model; line start IPM motor; loading condition; power 1 hp; synchronization capability; torque analysis; Induction motors; Permanent magnet motors; Reluctance motors; Rotors; Synchronization; Torque; Interior permanent magnet; brake torque; critical inertia; critical slip; run-up responses and synchronization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Machines & Drives Conference (IEMDC), 2013 IEEE International
Conference_Location :
Chicago, IL
Print_ISBN :
978-1-4673-4975-8
Electronic_ISBN :
978-1-4673-4973-4
Type :
conf
DOI :
10.1109/IEMDC.2013.6556288
Filename :
6556288
Link To Document :
بازگشت