DocumentCode
617779
Title
A new method of regulation based on a hysterisis error gain regulator applied in the WTGS
Author
Madaci, M. ; Kerdoun, D. ; Akkouchi, K.
Author_Institution
Dept. of Electr. Eng., Constantine 1 Univ., Constantine, Algeria
fYear
2013
fDate
9-11 May 2013
Firstpage
512
Lastpage
517
Abstract
This paper presents an autonomous wind turbine generation system consisting of wind turbine generators and back to back electronic power converters. Since this last one allows to connect the WTGS (Wind Turbine Generator System) that contain a variable margin of speed to the greed that work under a fixed speed. As conventional method of control usually use PI controller, the Mathematical model and parameters of the system should be known well, The output power of rectifier absorbed from the WTG is regulated by using controller such DC voltage of the system is controlled. We aim to demonstrate a new method of control that called HEGR (Hysteresis Error Gain Regulator) that give an enormous advantage than the additional regulators such as the (PI) and the VGPI (variable gain PI).
Keywords
PI control; mathematical analysis; power convertors; power system control; wind turbines; DC voltage; PI controller; WTGS; electronic power converters; hysterisis error gain regulator; mathematical model; wind turbine generation system; wind turbine generators; Generators; Hysteresis; MATLAB; Mathematical model; Radiation detectors; Wind turbines; (VGPI) (variable gain PI); HEGR (Hysteresis Error Gain Regulator); PI controller; WTGS (Wind Turbine Generator System); back to back electronic power converters; turbine generation system;
fLanguage
English
Publisher
ieee
Conference_Titel
Technological Advances in Electrical, Electronics and Computer Engineering (TAEECE), 2013 International Conference on