DocumentCode :
619330
Title :
Experimental investigation on the effect of conical valve shape and swirl generator to the performance of Ranque-Hilsch Vortex Tube
Author :
Wisnoe, Wirachman ; Ismail, Nur ; Remeli, Muhammad Fairuz ; Zakaria, Muhamad Fairul
Author_Institution :
Fac. of Mech. Eng., Univ. Teknol. MARA (UiTM), Shah Alam, Malaysia
fYear :
2013
fDate :
7-9 April 2013
Firstpage :
812
Lastpage :
817
Abstract :
Temperature at cold outlet, cold mass fraction and isentropic efficiency in the Ranque-Hilsch Vortex Tube (RHVT) are experimentally measured and derived. For the experiment, different pressures (absolute) (between 290 to 800 kPa) were applied as source, 3 types of swirl generator and 3 shapes of conical valve were used. The lowest temperature obtained during the experiment was -11.6 for a cold mass fraction (μc = 0.947) which gave the highest isentropic efficiency (ηis= 0.336) at source pressure of 790.2 kPa. However, the highest cold mass fraction (μc = 1.024) was given by source pressure of 790.2 kPa with isentropic efficiency (ηis) of 0.042 and the cold temperature was 20°C.
Keywords :
mass measurement; pipe flow; pipes; temperature measurement; valves; vortices; RHVT; Ranque-Hilsch vortex tube performance; cold mass fraction; cold temperature outlet; conical valve shape; isentropic efficiency; mass measurement; pressure 290 kPa to 800 kPa; swirl generator; temperature -11.6 degC; temperature 20 degC; temperature measurement; Cooling; Electron tubes; Generators; Heating; Shape; Temperature measurement; Valves; Ranque-Hilsch Vortex Tube; conical valve; isentropic efficiency; swirl generator;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Business Engineering and Industrial Applications Colloquium (BEIAC), 2013 IEEE
Conference_Location :
Langkawi
Print_ISBN :
978-1-4673-5967-2
Type :
conf
DOI :
10.1109/BEIAC.2013.6560248
Filename :
6560248