• DocumentCode
    621182
  • Title

    A reverse transmission mechanism for surveillance network in smart grid

  • Author

    Liang Tang ; Yun Rui ; Qian Wang ; Husheng Li ; Zhiyong Bu

  • Author_Institution
    Shanghai Inst. of Microsyst. & Inf. Technol., Shanghai, China
  • fYear
    2013
  • fDate
    14-19 April 2013
  • Firstpage
    61
  • Lastpage
    66
  • Abstract
    A reverse transmission mechanism for smart grid is introduced, in which the transmission robustness of ad-hoc netsegment is guaranteed. The goal is to address the deadlock issue caused by the broken down of the targeted tower , and to reduce transmission power consumption. Performance analysis of the new mechanism is presented, in which the configuration of different number of electrical towers is discussed. Upon examination of the simulation results, we conclude that the proposed mechanism provides lower latency and power consumption compared to the traditional transmission mechanism, and guarantees the transmission robustness for the smart grid.
  • Keywords
    power consumption; power transmission; smart power grids; surveillance; ad-hoc netsegment; deadlock issue; electrical towers; performance analysis; reverse transmission mechanism; smart grid; surveillance network; transmission power consumption; transmission robustness; Artificial neural networks; Internet; Logic gates; Optical fiber devices; Silicon;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer Communications Workshops (INFOCOM WKSHPS), 2013 IEEE Conference on
  • Conference_Location
    Turin
  • Print_ISBN
    978-1-4799-0055-8
  • Type

    conf

  • DOI
    10.1109/INFCOMW.2013.6562909
  • Filename
    6562909