DocumentCode :
621456
Title :
Method for determining the effective capacity variation depending on the discharge current for lead-acid calcium batteries
Author :
Dorin, Sabou ; Dan, Pop Dumitru ; Tirnovan, Radu
Author_Institution :
Electr. Power Syst. Dept., Tech. Univ. of Cluj-Napoca, Cluj-Napoca, Romania
fYear :
2013
fDate :
23-25 May 2013
Firstpage :
1
Lastpage :
6
Abstract :
In an isolated microgrid, the electricity produced by wind and/or photovoltaic generators in good conditions (sunny weather, wind) must be stored and consumed other times, according to the consumer´s profile. The most frequently used storing devices are the rechargeable batteries. Knowing their characteristics allows us an optimum sizing in terms of their operation and economic efficiency. The current article shows us a method by which, following some experimental measurements we can identify data about a SLI Lead battery and how they can be used in Peukert´s formula for calculating the effective capacity of such a battery at different discharge currents.
Keywords :
discharges (electric); distributed power generation; power generation economics; secondary cells; solar cells; Peukert´s formula; SLI lead battery; capacity variation; consumer profile; discharge current; discharge currents; economic efficiency; isolated microgrid; lead-acid calcium batteries; photovoltaic generators; rechargeable batteries; Batteries; Calcium; Discharges (electric); Equations; Generators; Lead; Wind; Energy; Lead-acid batteries; Peukert; microgrid; photovoltaic cells; solar energy; state-of-charge; storage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Advanced Topics in Electrical Engineering (ATEE), 2013 8th International Symposium on
Conference_Location :
Bucharest
Print_ISBN :
978-1-4673-5979-5
Type :
conf
DOI :
10.1109/ATEE.2013.6563500
Filename :
6563500
Link To Document :