DocumentCode
622911
Title
A dosimetric study using best-fit Cole-Cole parameters of biological tissues and organs in radio frequency band
Author
Sasaki, Kazuhiko ; Wake, Kanako ; Watanabe, Shigetaka
Author_Institution
Electromagn. Compatibility Lab., NICT, Koganei, Japan
fYear
2013
fDate
20-24 May 2013
Firstpage
630
Lastpage
633
Abstract
Best-fit Cole-Cole parameters for biological tissues and organs are proposed in this study. The sensitivity of the energy absorption is evaluated using a Mie series solution as a preliminary study. Numerical dosimetry studies of the energy absorption of the human models following radio frequency exposure were performed using the best-fit Cole-Cole parameters, and the results were compared with the standard Cole-Cole parameters that are normally used.
Keywords
Mie scattering; biological effects of microwaves; biological organs; biological tissues; dosimetry; electromagnetic wave absorption; Mie series solution; best-fit Cole-Cole parameter; biological organ; biological tissue; energy absorption sensitivity; human model; numerical dosimetry; radio frequency band; radio frequency exposure; Absorption; Biological tissues; Dielectric measurement; Dielectrics; Dosimetry; Parametric statistics; Permittivity;