DocumentCode :
62386
Title :
Loss minimisation in λ/4 impedance transformers using multiple lλ4 segments
Author :
Li, Cong ; Ricketts, David S.
Author_Institution :
ECE, Carnegie Mellon Univ., Pittsburgh, PA, USA
Volume :
49
Issue :
4
fYear :
2013
fDate :
Feb. 14 2013
Firstpage :
274
Lastpage :
276
Abstract :
Presented is an analysis of loss in quarter-wavelength impedance transformers. It is shown that the loss of an impedance transformer, S21, is a function not only of the dielectric and conductor loss, but also the transformation ratio. S21 is derived as a function of both loss and transformation ratio and it is shown that for high transformation ratios, using two or even three quarter-wavelength impedance transformers results in an overall lower loss.
Keywords :
dielectric losses; transformers; transmission lines; λ/4 impedance transformer; conductor loss; dielectric loss; loss minimisation; multiple λ/4 segment; quarter-wavelength impedance transformer;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el.2012.3382
Filename :
6464683
Link To Document :