• DocumentCode
    627812
  • Title

    Challenges in recording and stimulation of living neural network based on original micro-electrode array (MEA) developments

  • Author

    Cottance, M. ; Nazeer, S. ; Rousseau, L. ; Lissorgues, Gaelle ; Joucla, S. ; Yvert, B. ; Lewis, N. ; Bornat, Yannick ; Renaud, S.

  • Author_Institution
    ESIEE PARIS - ESYCOM, Univ. Paris Est, Noisy-le-Grand, France
  • fYear
    2013
  • fDate
    16-19 June 2013
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Recent research in micro-manufacturing together with new technologies in bioelectronics can lead to neuroscience applications to explore the properties of neural networks. Micro Electrode Arrays correspond to a well suited tool to either stimulate or record large populations of cultured cells and tissues. Based on existing state-of-the-art MEAs, the paper describes original developments to improve either recording or stimulation of neural networks, focusing on action potential discrimination.
  • Keywords
    microelectrodes; neural nets; bioelectronics; living neural network; micromanufacturing; neuroscience application; original microelectrode array MEA development; stimulation; Arrays; Biological neural networks; Electric potential; Electrodes; Shafts; Standards; Wavelet transforms;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    New Circuits and Systems Conference (NEWCAS), 2013 IEEE 11th International
  • Conference_Location
    Paris
  • Print_ISBN
    978-1-4799-0618-5
  • Type

    conf

  • DOI
    10.1109/NEWCAS.2013.6573645
  • Filename
    6573645