DocumentCode :
631262
Title :
Effect of shielding, grounding, EMI filters & ferrite beads on radiated & conducted emissions
Author :
Rafiq, M.A. ; Amin, M. ; Yousaf, J.
Author_Institution :
SUPARCO, Lahore, Pakistan
fYear :
2013
fDate :
12-14 June 2013
Firstpage :
583
Lastpage :
588
Abstract :
In this paper measured results are presented to show the effect of shielding slots, seems and cables interconnecting different subsystems on the radiated emissions. It is shown that by using proper shielding Radiated Emission (RE) levels can be reduced by as much as 40dB. Similarly the attenuation of at least 20 dB in measured voltage levels in the conducted emission tests can be achieved by the use of π-filters and chassis ground. In case of power unit, it has also been diagnosed that major cause of conducted emissions (CE) is the switching of DC-DC convertor. Measurements with ferrite beads showed that these are useful only at frequencies below few megahertz.
Keywords :
DC-DC power convertors; earthing; electromagnetic interference; electromagnetic shielding; ferrites; filters; π-filters; DC-DC convertor; EMI filters; chassis ground; conducted emissions; ferrite beads; grounding; radiated emissions; shielding effect; shielding slots; Cable shielding; Converters; Electromagnetic interference; Frequency measurement; Power cables; Power measurement; Signal processing; Conducted Emissions (CE); Conducted Susceptibility (CS); Electromagnetic Interference (EMI); Electromagnetic compatibility (EMC); LISN (Line Impedance Stabilization Network); Radiated Emissions (RE); Radiated Susceptibility (RS);
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Recent Advances in Space Technologies (RAST), 2013 6th International Conference on
Conference_Location :
Istanbul
Print_ISBN :
978-1-4673-6395-2
Type :
conf
DOI :
10.1109/RAST.2013.6581278
Filename :
6581278
Link To Document :