DocumentCode
63259
Title
An Improved Current-Comparator-Based Power Standard With an Uncertainty of 2.5
Author
So, Eddy ; Arseneau, R. ; Angelo, David
Author_Institution
Meas. Sci. & Stand. Portfolio, Nat. Res. Council of Canada, Ottawa, ON, Canada
Volume
62
Issue
6
fYear
2013
fDate
Jun-13
Firstpage
1704
Lastpage
1709
Abstract
An improved power standard derived from a current comparator power bridge for calibrating active/reactive power and energy meters under sinusoidal conditions is described. Measurements can be made at any power factor from zero lag through unity to zero lead, at positive or negative power, at 120 V, 5 A, and 50 or 60 Hz. The improved power standard has an estimated uncertainty of not more than 2.5 μW/VA at k = 1. Special high-accuracy current and voltage range extenders have been incorporated to extend the current and voltage ranges up to 200 A and 1200 V, respectively.
Keywords
calibration; current comparators; power meters; active-reactive power calibration; current 5 A; energy meter calibration; improved current-comparator-based power standard; power factor; sinusoidal conditions; voltage 120 V; Bridge circuits; Capacitors; Reactive power; Resistors; Standards; Uncertainty; Windings; Current comparator; power bridge; power measurement; power standard; uncertainty;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.2013.2239015
Filename
6466383
Link To Document