• DocumentCode
    63316
  • Title

    Depressurised reservoirs for portable fluid extraction in SU-8-based microfluidic systems

  • Author

    Aracil, Carmen ; Perdigones, Francisco Antonio ; Moreno, Juan Manuel ; Luque, Antonio ; Flores, Guadalupe ; Quero, Jose M.

  • Author_Institution
    Escuela Super. de Ing., Dept. de Ing. Electron., Univ. de Sevilla, Sevilla, Spain
  • Volume
    9
  • Issue
    11
  • fYear
    2014
  • fDate
    11 2014
  • Firstpage
    821
  • Lastpage
    824
  • Abstract
    A depressurisation method to build SU-8 chambers as pneumatic energy reservoirs is described. The method consists in a combination of injection/extraction of uncrosslinked SU-8 and its exposure in different steps, intended to set the pressure of a chamber below atmospheric. These chambers are intended to be integrated with an actuation system to perform the extraction of fluids from the outside to the inside of a microfluidic SU-8 lab-on-a-chip. This method improves the portability of the platform because external pumps used to impulse the fluids can be avoided.
  • Keywords
    lab-on-a-chip; microfluidics; pneumatic systems; SU-8 chambers; actuation system; depressurisation method; depressurised reservoirs; external pumps; microfluidic SU-8 lab-on-a-chip; pneumatic energy reservoirs; portable fluid extraction;
  • fLanguage
    English
  • Journal_Title
    Micro & Nano Letters, IET
  • Publisher
    iet
  • ISSN
    1750-0443
  • Type

    jour

  • DOI
    10.1049/mnl.2014.0481
  • Filename
    6969296