• DocumentCode
    633596
  • Title

    Numerical Analysis on Performance of Diffuser Aim at Entrance Bucket at Different Installation Site

  • Author

    Zhu Xiuchuan

  • Author_Institution
    Anhui Nat. Defense Vocational Coll., Luan, China
  • fYear
    2013
  • fDate
    29-30 June 2013
  • Firstpage
    842
  • Lastpage
    844
  • Abstract
    Aiming at entrance bucket at different installation site, inner flow field of diffuser was simulated and analyzed, get graphs of static pressure coefficient (Cp), atmospheric pressure coefficient (Cpa) and efficiency (n). Though analysis and get rule of performance of diffuser aim at entrance bucket at different installation site, the rule provides theoretical foundation on design of fanner diffuser.
  • Keywords
    atmospheric pressure; fans; mechanical engineering computing; numerical analysis; atmospheric pressure coefficient; entrance bucket; fanner diffuser aim; inner flow field; installation site; numerical analysis; static pressure coefficient; Automation; Manufacturing; diffuser; efficiency; entrance bucket; flow field; numerical analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Digital Manufacturing and Automation (ICDMA), 2013 Fourth International Conference on
  • Conference_Location
    Qingdao
  • Type

    conf

  • DOI
    10.1109/ICDMA.2013.199
  • Filename
    6598121