DocumentCode
636255
Title
Evaluation of titanium mesh electrode using for transcutaneous intrabody communication by tissue-electrode impedance
Author
Okamoto, Eiji ; Kikuchi, Shinji ; Mitamura, Yoshinori
Author_Institution
Grad. Sch. of Sci. & Eng., Tokai Univ., Sapporo, Japan
fYear
2013
fDate
3-7 July 2013
Firstpage
667
Lastpage
670
Abstract
We developed a new transcutaneous communication system (TCS) that uses the human body as a conductive medium for monitoring and controlling an artificial heart and other implanted artificial organs in the body. The TCS is able to transmit data between everywhere on the surface of the body and everywhere inside the body, however poor contact between tissue and the electrode influences on communication performance. Thus in this study, we have developed a titanium mesh electrode for the internal transmission electrode. The titanium mesh electrode has advantages of histocompatibility and mechanical stable contact to the tissue by infiltration of the tissue into the titanium mesh like as an extracellular matrix. There titanium mesh electrodes were implanted separately into the dorsal region of the rats under the skin and the electrical performance of the titanium mesh electrode was evaluated by means of measuring the electrode-tissue boundary resistance. In vivo experimental results showed that the titanium mesh electrode had stable mechanical contact to tissue and lower electrode -tissue boundary resistance. In conclusion, the titanium mesh electrode showed excellent histocompatibility it realized stable contact to tissue as anchor, and it had superior electrical property. Thus the titanium mesh electrode is suitable for an internal electrode of the TCS to monitor artificial organs implanted into the body.
Keywords
artificial organs; bioelectric phenomena; biological tissues; biomedical communication; biomedical electrodes; biomedical materials; mechanical stability; artificial heart controlling; artificial heart monitoring; data transmission; electrical property; electrode-tissue boundary resistance measurement; extracellular matrix; histocompatibility; internal transmission electrode; mechanical stability; rat dorsal region; tissue infiltration; tissue-electrode impedance; titanium mesh electrode evaluation; transcutaneous intrabody communication system; Contacts; Electrical resistance measurement; Electrodes; Immune system; Impedance; Impedance measurement; Titanium;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
Conference_Location
Osaka
ISSN
1557-170X
Type
conf
DOI
10.1109/EMBC.2013.6609588
Filename
6609588
Link To Document