Title :
Automatic prostate segmentation in cone-beam computed tomography images using rigid registration
Author :
Boydev, Christine ; Pasquier, David ; Derraz, Foued ; Peyrodie, Laurent ; Taleb-Ahmed, A. ; Thiran, Jean-Philippe
Author_Institution :
Lab. d´Autom., de Mec. et d´Inf. Industrielles et Humaines (LAMIH), Univ. de Valenciennes et du Hainaut-Cambresis, Valenciennes, France
Abstract :
We propose to evaluate automatic three-dimensional gray-value rigid registration (RR) methods for prostate localization on cone-beam computed tomography (CBCT) scans. In total, 103 CBCT scans of 9 prostate patients have been analyzed. Each one was registered to the planning CT scan using different methods: (a) global RR, (b) pelvis bone structure RR, (c) bone RR refined by local soft-tissue RR using the CT clinical target volume (CTV) expanded with a 1, 3, 5, 8, 10, 12, 15 or 20-mm margin. To evaluate results, a radiation oncologist was asked to manually delineate the CTV on the CBCT scans. The Dice coefficients between each automatic CBCT segmentation - derived from the transformation of the manual CT segmentation - and the manual CBCT segmentation were calculated. Global or bone CT/CBCT RR has been shown to yield insufficient results in average. Local RR with an 8-mm margin around the CTV after bone RR was found to be the best candidate for systematically significantly improving prostate localization.
Keywords :
bone; computerised tomography; image registration; image segmentation; medical image processing; CBCT scans; CT clinical target volume; CTV; Dice coefficients; automatic CBCT segmentation; automatic prostate segmentation; automatic three-dimensional gray-value rigid registration method; bone CT-CBCT rigid registration; cone-beam computed tomography images; cone-beam computed tomography scans; global CT-CBCT rigid registration; local soft-tissue rigid registration; pelvis bone structure rigid registration; prostate localization; prostate patients; radiation oncologist; size 1 mm; size 10 mm; size 12 mm; size 15 mm; size 20 mm; size 3 mm; size 5 mm; size 8 mm; Bones; Computed tomography; Image segmentation; Manuals; Pelvis; Planning; X-ray imaging; Rigid registration; cone-beam computed tomography; image-guided radiotherapy; prostate cancer; segmentation;
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
Conference_Location :
Osaka
DOI :
10.1109/EMBC.2013.6610420