DocumentCode
636861
Title
Wireless patch sensor for remote monitoring of heart rate, respiration, activity, and falls
Author
Chan, Alexander M. ; Selvaraj, Nandakumar ; Ferdosi, Nima ; Narasimhan, Ravi
Author_Institution
Vital Connect Inc., Campbell, CA, USA
fYear
2013
fDate
3-7 July 2013
Firstpage
6115
Lastpage
6118
Abstract
Unobtrusive continuous monitoring of important vital signs and activity metrics has the potential to provide remote health monitoring, at-home screening, and rapid notification of critical events such as heart attacks, falls, or respiratory distress. This paper contains validation results of a wireless Bluetooth Low Energy (BLE) patch sensor consisting of two electrocardiography (ECG) electrodes, a microcontroller, a tri-axial accelerometer, and a BLE transceiver. The sensor measures heart rate, heart rate variability (HRV), respiratory rate, posture, steps, and falls and was evaluated on a total of 25 adult participants who performed breathing exercises, activities of daily living (ADLs), various stretches, stationary cycling, walking/running, and simulated falls. Compared to reference devices, the heart rate measurement had a mean absolute error (MAE) of less than 2 bpm, time-domain HRV measurements had an RMS error of less than 15 ms, respiratory rate had an MAE of 1.1 breaths per minute during metronome breathing, posture detection had an accuracy of over 95% in two of the three patch locations, steps were counted with an absolute error of less than 5%, and falls were detected with a sensitivity of 95.2% and specificity of 100%.
Keywords
Bluetooth; accelerometers; biomedical electrodes; electrocardiography; gait analysis; microcontrollers; patient monitoring; pneumodynamics; wireless sensor networks; BLE transceiver; ECG; RMS error; breathing exercises; daily living activity; electrocardiography electrodes; heart rate variability; mean absolute error; microcontroller; posture detection; remote monitoring; respiration; respiratory distress; respiratory rate; running; simulated falls; stationary cycling; steps counting; time-domain HRV measurements; triaxial accelerometer; walking; wireless Bluetooth low energy patch sensor; Electrocardiography; Heart rate variability; Legged locomotion; Monitoring; Wireless communication; Wireless sensor networks;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
Conference_Location
Osaka
ISSN
1557-170X
Type
conf
DOI
10.1109/EMBC.2013.6610948
Filename
6610948