DocumentCode :
63688
Title :
On-line decision tree-based insulation assessment employing mathematical morphology filters for HV cables
Author :
Ashtiani, Mohsen ; Shahrtash, S.
Author_Institution :
Center of Excellence for Power Syst. Autom. & Oper., Iran Univ. of Sci. & Technol. (IUST), Tehran, Iran
Volume :
20
Issue :
4
fYear :
2013
fDate :
Aug-13
Firstpage :
1347
Lastpage :
1355
Abstract :
In this paper a new approach is given for insulation assessment of HV cables based on investigating the void size and/or remained insulation thickness (RIT), while the void is considered as the partial discharge source. The proposed decision tree based algorithm has well kept its capability in classifying the void size under different conditions of geometrical properties of the void such as size, depth and location; cable characteristics such as age and temperature; and also environmental noise. The procedure includes four stages which are, signal de-noising, PD detection, feature generation and compensation and finally void classification. In the first stage, the prerequisite task of de-noising is performed by a filter based on Mathematical Morphology (MM). PD detection stage is carried out based on mathematical morphology functions, too. In the feature generation stage, a compensation procedure is employed, in order to diminish the effect of pulse propagation along the cable on the PD features used for classification. Finally, in the last stage, void classification is done by Decision tree. Simulation results have shown high accuracy of the proposed insulation assessment method. In addition, in the stages of noise reduction and PD detection, performances of the algorithms are examined by experimental data which is recorded in the field.
Keywords :
decision trees; power cable insulation; power filters; HV cables; discharge source; mathematical morphology filters; online decision tree-based insulation assessment; remained insulation thickness; void size; Cable insulation; Classification algorithms; Decision trees; Estimation; Partial discharges; Power cables; Partial discharge; decision tree; high voltage power cables; insulation assessment; mathematical morphology; remained insulation thickness;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2013.6571455
Filename :
6571455
Link To Document :
بازگشت