    Experimental Analysis of 1-3 Piezocomposites for High-Intensity Focused Ultrasound Transducer Applications

  • Author

    Gin-Shin Chen ; Hsin-Chih Liu ; Yu-Cheng Lin ; Yu-Li Lin

  • Author_Institution
    Div. of Med. Eng. Res., Nat. Health Res. Inst., Zhunan, Taiwan
  • Volume
    60
  • Issue
    1
  • fYear
    2013
  • fDate
    Jan. 2013
  • Firstpage
    128
  • Lastpage
    134
  • Abstract
    Piezocomposites with 1-3 connectivity have been extensively used in medical imaging transducers and high-intensity focused ultrasound transducers, but most studies of 1-3 piezocomposites address medical imaging applications. The purpose of this study was to completely investigate 1-3 composites specifically for high-power ultrasonic transducer applications via a series of experimental analyses. PZT4-epoxy composite focused transducers with various aspect ratios and volume fractions were constructed in-house for the evaluation of the coupling factor, dielectric loss tangent, quality factor, bandwidth, acoustic impedance, and electroacoustic efficiency. The experimental analyses demonstrated that although the coupling factor of composite transducers was higher than that of the ceramic transducer, the composite transducers had a lower efficiency due to the high dielectric loss and high mechanical energy loss of the composites. In addition, the bandwidth and acoustic impedance of composite transducers were superior to the ceramic transducer. For the composite transducers, the efficiency and acoustic impedance were inversely proportional to the aspect ratio and linearly proportional to the volume fraction. The coupling of inter pillars that are too close to each other could cause a significant decrease in the efficiency of the composite transducer. With an appropriate design in terms of the aspect ratio, volume fraction, and PZT-pillar spacing, a high-efficiency composite high-intensity focused ultrasound transducer can be achieved.
  • Keywords
    acoustic impedance; biomedical transducers; composite materials; piezoceramics; ultrasonic transducers; 1-3 piezocomposite; acoustic impedance; aspect ratio; bandwidth; ceramic transducer; coupling factor; dielectric loss tangent; electroacoustic efficiency; high intensity focused ultrasound transducer; high power ultrasonic transducer; medical imaging transducers; quality factor; volume fraction; Acoustics; Bandwidth; Ceramics; Couplings; Impedance; Probes; Transducers; High intensity; piezocomposites; transducer; ultrasound; Ceramics; Electric Impedance; Equipment Design; High-Intensity Focused Ultrasound Ablation; Materials Testing; Transducers;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2012.2226881
  • Filename
    6341800