DocumentCode :
646692
Title :
Determination of the “Quasi-Ideal Reverberation Chamber Minimal Frequency” according to loading
Author :
Adardour, Aziz ; Andrieu, Guillaume ; Reineix, Alain
Author_Institution :
OSA Dept., XLIM Lab., Limoges, France
fYear :
2013
fDate :
5-9 Aug. 2013
Firstpage :
213
Lastpage :
216
Abstract :
An original method allowing to define from measurements a specific frequency called “Quasi-Ideal Reverberation Chamber Minimal Frequency” (QIRCMF) is presented. The QIRCMF corresponds to the frequency where a mode stirred reverberation chamber is considered as working in a “quasi-ideal regime”. After a definition of what means “quasi-ideal” reverberation chamber, the method is presented. The method is based on 1) the assessment of the electromagnetic field distributions obtained in the working volume (in comparison with the distributions obtained in the ideal model defined in [1]) and 2) the assessment of the correlation of the electromagnetic field over one mode stirrer revolution. Experimental results clearly show that the QIRCMF can be highly reduced by introducing in the mode stirred reverberation chamber but far from the working volume a little amount of loading.
Keywords :
electromagnetic fields; reverberation chambers; QIRCMF; electromagnetic field distributions; quasi ideal regime; quasi ideal reverberation chamber minimal frequency; stirred reverberation chamber; Correlation; Frequency measurement; Loading; Q-factor; Reverberation chambers; Standards;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (EMC), 2013 IEEE International Symposium on
Conference_Location :
Denver, CO
ISSN :
2158-110X
Print_ISBN :
978-1-4799-0408-2
Type :
conf
DOI :
10.1109/ISEMC.2013.6670411
Filename :
6670411
Link To Document :
بازگشت