DocumentCode
647911
Title
Fast short circuit power switch fault detection in cascaded H-bridge multilevel converter
Author
Shahbazi, Moein ; Zolghadri, Mohammad Reza ; Poure, Philippe ; Saadate, Shahrokh
Author_Institution
Center of Excellence in Power Syst. Manage. & Control (CEPSMC), Sharif Univ. of Technol., Tehran, Iran
fYear
2013
fDate
21-25 July 2013
Firstpage
1
Lastpage
5
Abstract
Multilevel converters are being widely used in a large number of power electronics applications. Due to the increased number of switching devices, they are more likely to have faults in their switches than the conventional converters. In order to have a balanced operation after a short circuit power switch fault occurrence, it is necessary to detect the fault location. In this paper, a fast power switch fault detection method is presented to identify the fault location. This method only needs one additional voltage sensor per phase, and is faster compared to most of the existing methods. Also it is easy for implementation on a FPGA chip. The proposed method is verified by computer simulations.
Keywords
electric sensing devices; fault location; field programmable gate arrays; switching convertors; FPGA chip; cascaded H-bridge multilevel converter; computer simulations; fast short circuit power switch fault detection; fault location; power electronics applications; voltage sensor; Electrical fault detection; Fault detection; Inverters; Switches; Voltage measurement; cascaded H-bridge converter; multilevel converter; power switch fault detection; short circuit fault;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Society General Meeting (PES), 2013 IEEE
Conference_Location
Vancouver, BC
ISSN
1944-9925
Type
conf
DOI
10.1109/PESMG.2013.6672461
Filename
6672461
Link To Document